Chlorinator off high salt amps - To effectively clean the cell, it is recommended to follow these steps: 1. Power off the salt system. 2. Disconnect the cell from the system. 3. Rinse the cell with a high-pressure hose, removing any debris or scale buildup. 4. Inspect the cell for any visible signs of damage, such as cracks or broken plates.

 
The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo cell, that exceeds the allowable threshold for the programmed cell model. Verify chlorinator readings Verify cell programming... Page 31 4. Chlorinator OFF, High Salt/Amps (cont.) The salt concentration will need to .... Elden ring svg

The CircuPool® CORE55 Salt Chlorine Generator is high performance, for a luxurious saltwater swimming experience, eliminating chlorine pool maintenance. Home; Compare; Learn More; My Account; Support (888) 206-9938 [email protected] Menu. ... Revolutionary CORE saltwater chlorinators feature advanced digital electronics & easy installation.Rock salt may reduce accidents during icy weather, but it can also have serious, negative effects on aquatic ecosystems. When the weather takes a wintery turn, many cities and muni...However, when I tested it with the salt strip again, it read 2800ppm. This salt level would be fine for the regular salt chlorinator but I found nothing online about a low salt chlorinator. Does anyone know if 2800ppm is too high for a low salt chlorinator system? I also plan on just taking a sample of water for professional testing tomorrow.I wanted to share my experience and success in fixing my "Chlorinator Off / High Salt/Amps" issue on my Aquarite panel. I'd replaced my Hayward T-9 with a legit …Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ...The “High Salt” light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or, most …My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm.High Salt/Amps The “Chlorinator Off High Salt” warning comes on when the current exceeds 8 amps regardless of the salt level. This can be caused by high salt but also by high water temperatures. If it says high salt, the amps were above 8.0. If the volts are more than 32 at any point, the circuit board is probably damaged.In fact, most of the time, they’re easier. BUT they are a little different. 1. Inspect regularly for scale. One of the biggest problems with salt chlorine generators is that they tend to produce a lot of scaling (or calcium deposits). To keep this at a manageable level, check your generator every 2-3 months. However, when I tested it with the salt strip again, it read 2800ppm. This salt level would be fine for the regular salt chlorinator but I found nothing online about a low salt chlorinator. Does anyone know if 2800ppm is too high for a low salt chlorinator system? I also plan on just taking a sample of water for professional testing tomorrow. Only chlorinator off, test salt level (which is the problem), instant salt chlorinator off, flow switch- flow, cell temp sensor-82f, water sensor-open circuit, air sensor-open circuit. Main software Rev 4.45, display software Rev 3.13. Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ... Chlorinator OFF, High Salt/Amps (cont.) The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo …I just replaced my T-cell 86 Turbo cell with a newly T-cell 54. When the system starting in race I get this message, "Chlorinator Off Elevated Salt/Amps." Then late for the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 8147, which EGO know is way too great. I... Problem #2: High Salt Levels. High salt levels in your pool can cause damage to your salt cell and reduce its lifespan. It can also cause skin and eye irritation for swimmers. If you’re noticing high salt levels, start by testing the water and checking the cell for buildup or corrosion. If there is buildup, clean the cell using a soft brush ... It would suggest the salt levels are too high based on the error reporting, drain some of the water and top it up and this will reduce your salt level, you want it ideally less than 3500 …Home - Trouble Free Pool | Trouble Free PoolThe type of bonding found in sodium chloride is called ionic bonding. Ionic bonding is the attraction between two atoms with opposite charges. In sodium chloride, sodium has a posi...Low salt. The Salt Cell needs a certain amount of salt in the water to convert the salty water to chlorine. The correct salt level is important to cell life and the effective operation of your chlorinator. A typical pool of around 50,000 litres requires 200kg of salt to initially set-up the pool to 4,000ppm.This chart is most useful for basic first step troubleshooting and diagnostics of AutoPilot Pool Pilot Digital (DIG-220), AutoPilot Pool Pilot Digital “Total Control” (75003) and AutoPilot Pool Pilot Soft Touch (ST-220) units. It is highly recommended that you use our web form to reach one of our technicians for further assistance.How To Tell If Salt Cell Needs Replacing | Best Price Pool Equipment. Skip to content. Fast Delivery Available! 211 Stirling Highway, Claremont, WA 6010. 0412 561 620. Email Nicole. About Nicole. Nicole’s Advice. Warranty.The AstralPool VX salt chlorinator continuously generates the precise level of chlorine into your pool with the convenience of a touchpad to save you time. Toggle navigation. ... 8.9 amps Programming: Clock timer settings: 4 timers Video. Run-on Feature. Play. Video. Safety Backwash. Play. Video. Chlorine Output Control. Play.The no flow warning light on your salt water chlorinator is a protective feature that will shut the salt cell’s chlorine production down to protect the cell from damage. Chlorine production won’t start up again until the water flow has reached the minimum level required. Typically a low (or no) water flow is due to a blocked or full side ...In fact, most of the time, they’re easier. BUT they are a little different. 1. Inspect regularly for scale. One of the biggest problems with salt chlorine generators is that they tend to produce a lot of scaling (or calcium deposits). To keep this at a manageable level, check your generator every 2-3 months.The aquapod is saying high salt/high amps, chlorinator off. The diagnostics is showing 2700 ppm salt (not high) and a salt test strip showed something closer to 500. A local pool guy suggested that the mother board must be replaced. I did see posts on here regarding a relay, solder problem. chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack. Chlorinator OFF, High Salt/Amps (cont.) The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo …Check and balance your pool chemistry: Regularly test and balance your pool chemistry, paying attention to pH levels and cyanuric acid levels. High pH or low cyanuric acid can impact chlorine effectiveness. Maintain a pH level of 7.2-7.6 and a CYA level of 30-50 ppm to reduce strain on the salt cell.High salt/amps Salt has been tested and is 3100, new t-cell purchased and still getting the message. Contractor's Assistant: I understand that youre experiencing high salt/amps despite testing the salt level and replacing the t-cell, but dont worry, our Expert will be able to help you troubleshoot and resolve this issue.Set TurboCell® Type & Reset Average Salt 10-11 Adjust Chlorine Output & Clean TurboCell 12-15 Troubleshooting: Pg. 16-38 1. Check Salt & Inspect Cell: flashing or ON 17-20 2. High Salt: LED ON 21-25 3. No Flow: LED flashing or ON 26-30 4. Display ONLY, Lights ONLY, or Neither 31-36 5. LCD: Displaying HOT or COLD _ 37-38Rock salt may reduce accidents during icy weather, but it can also have serious, negative effects on aquatic ecosystems. When the weather takes a wintery turn, many cities and muni... Problem #2: High Salt Levels. High salt levels in your pool can cause damage to your salt cell and reduce its lifespan. It can also cause skin and eye irritation for swimmers. If you’re noticing high salt levels, start by testing the water and checking the cell for buildup or corrosion. If there is buildup, clean the cell using a soft brush ... salt level in the pool and the system may turn the chlorinator off. Maximum Current (Amps) before shutdown Page 10 3. Chlorinator Off: Test Salt Level Message T-CELL-3 5.50 T-CELL-9 10.00 T-CELL-5 6.75 T-CELL-15 10.00SKU # PLC1400. The Jandy AquaPure ® salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Rely on its sturdy design and simple features to create your saltwater oasis. Read more. Find a Dealer.Sep 15, 2019 · The shock is great but that doesn't address the salt cell and the shock will wear off. Make sure the ph is in the 7.2 to about 7.8 range and your Calcium which is the big reason you have to clean the cell less than 450 ppm. Jun 26, 2016 · Help please! My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm. Chlorinator OFF, High Salt/Amps The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo cell, that exceeds the allowable threshold for the programmed cell model. Test salt level Reset chlorinator in diagnostics... Page 30 4. Chlorinator OFF, High Salt/Amps (cont.)Salt made in Asia had by far the most microplastics of all the samples, which correlates with where plastic most often enters the ocean. There’s microplastic in that table salt. A ...This comes in handy when it comes to determining the best solution. Below are 3 of the most common causes of failure in the salt cell’s function. 1. Wear and tear due to continuous use. This usually leads to problems like PCB electric failure and disconnection of plates. 2. High salt concentrations in water.Only chlorinator off, test salt level (which is the problem), instant salt chlorinator off, flow switch- flow, cell temp sensor-82f, water sensor-open circuit, air sensor-open circuit. Main software Rev 4.45, display software Rev 3.13.I've bought after market new t-15 salt cell and put in new board for t-15 cell and still reads high salt 4200 compared to pool store water sample 3200ppm, don't know what else to try. Changed sand in …2. Chlorinator OFF, High Salt/Amps The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo cell, that exceeds the allowable threshold for the programmed cell model. Test salt level Reset chlorinator in diagnostics... Reset Average Salt & Adjust Chlorinator Output. 6. Adjust ORP Set Points & Adjust Heater Set Points. 8. Clear Inspect Cell Message & Set a Pump Schedule. 10. Change VSP Speed Settings & Clean the Turbo Cell. 12. Whether you’re welding or working in a power plant, the ability to calculate three-phase power can prove handy. Read on to learn more about converting three-phase power to amps. An...I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read moreMay 18, 2019 · I have a Hayward goldline pro logic with a message that reads chlorinator off high salt amps. The values are at 40.58v, 10.08a. ... System check, chlorinator off very ... Aug 23, 2009 ... ... Salt, High Salt, and ... The Goldline tech said the “High Salt/Amps ... Make sure you turn your chlorinator Off for 24 hours every time you add salt ...TCELLS340 generates up to 1.45 lbs. of chlorine per day at high salt or up to 0.725 lbs at low salt levels. TCELLS325 generates up to 0.98 lbs. of chlorine per day at high salt or up to 0.49 lbs at low salt levels. TCELLS315 generates up to 0.53 lbs. of chlorine per day at high salt or up to 0.265 lbs at low salt levels. Aquarite Cell PlatesFrom https://www.justanswer.com/ythiJustAnswer Customer: I have a high salt amps message.JustAnswer Customer: chlorinator off when I start chlorinator the va...Adjusting Chlorine Output High Salt LED ON No Flow LED flashing or ON No LED's/LCD display Low/High Cell temperature Cell cleaning instructions ... 5.7 amps 4.5 amps Super Chlorinate Auto Off Super Chlorinate Auto Off To switch polarities, cycle Main Switch from AUTO* OFF + AUTO. Page 3 T-15 Amp Range:Rock salt may reduce accidents during icy weather, but it can also have serious, negative effects on aquatic ecosystems. When the weather takes a wintery turn, many cities and muni... My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm. Apr 19, 2019 · I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more • The AquaRite 100 Salt Chlorine Generator is designed to convert 99% pure salt into chlorine gas(CL. 2 (g)). • When CL. 2 (g) is dissolved in water it creates Hypochlorous Acid (HOCL) to sanitize the pool. • The conversionoccurs in the electrolytic cell, also known as the cell (used throughout this guide).I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read morePush 3, Cell Amperage - The cell's average amperage when chlorine is being generated varies with the size of cell installed: T-15 is 3.1 to 8.0 amps; T-9 is 2.3 to 6.7 amps; T-5 is 1.9 to 5.7 amps; and t-3 is 1.3 to 4.5 amps. When the cell is not generating chlorine the amperage is 0.Apr 5, 2020 ... SWIMMINGPOOL #MAINTENANCE #TROUBLEFREEPOOL Fix the common chlorinator off - no flow error. DIY it for huge savings.Jun 26, 2016 · Help please! My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm. Fasten the Turbo Cell to Cell Cleaning Stand with the cord side down. Before filling the Turbo Cell with a muriatic acid solution, place a container underneath to avoid any spills. Fill the Turbo Cell to the top with the solution and let soak for 15 minutes. Empty the Turbo Cell and inspect. If clean, rinse with a hose and reinstall.From https://www.justanswer.com/ythiJustAnswer Customer: I have a high salt amps message.JustAnswer Customer: chlorinator off when I start chlorinator the va... chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack. Fix your Hayward Salt Chlorinator system instead of replacing it. When the generating light shuts off after a few seconds when you turn your system on, a $3 ...2. Chlorinator OFF, High Salt/Amps The message ‘Chlorinator Off – High Salt/Amps’ indicates that the ProLogic has detected an amperage draw, from the turbo cell, that exceeds the allowable threshold for the programmed cell model. Test salt level Reset chlorinator in diagnostics... I just replaced my T-cell 86 Turbo cell with a newly T-cell 54. When the system starting in race I get this message, "Chlorinator Off Elevated Salt/Amps." Then late for the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 8147, which EGO know is way too great. I... TCELLS340 generates up to 1.45 lbs. of chlorine per day at high salt or up to 0.725 lbs at low salt levels. TCELLS325 generates up to 0.98 lbs. of chlorine per day at high salt or up to 0.49 lbs at low salt levels. TCELLS315 generates up to 0.53 lbs. of chlorine per day at high salt or up to 0.265 lbs at low salt levels. Aquarite Cell PlatesAug 23, 2020 · I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. When salt reading drop bellow 2300 ppm is Aqua Rite will shoot down output to cell( generating LED off). Chlorine generation will stop even actual salt level in pool is 2500-3400 ppm. But cell is still OK and can generate chlorine. Problem is caused by salinity sensor that is part of cell, so we need to clean,calibrate it or replaced. Page 20: Chlorinator Off, High Salt/Amps 2. Chlorinator OFF, High Salt/Amps (cont.) The salt concentration will need to reduced. To calculate how much water to drain, follow the formula provided below (Proportional Method): Step 2D Part I Part 1: Take the average depth of the pool in inches and multiply that by 3200. Page 21: Chlorinator Off ... Apr 17, 2012 · Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt... If all zeros or if Chlorinator Off Percentage Met, press ~+ key. IF, after a short countdown delay, the display does not revert to zeros, refer to step 3. NOTE: The main circulation pump MUST be ON and the chlorinator AND flow switch MUST have flow to successfully complete this process. 2 Above is an example of the updated instant salt reading ... Technical Specifications. Produces 25 grams of chlorine gas per hour. Ideal salt level 3000ppm with water at 25°C. Suits outdoor pools up to 90,000 litres. Suits indoor pools up to 150,000 litres. Cell has 50mm unions (reducers not included) 5 …Human Salt Consumption - Human salt consumption should be regulated because too much salt can cause problems, such as hypertension. Learn more about human salt consumption. Adverti...salt level in the pool and the system may turn the chlorinator off. Maximum Current (Amps) before shutdown Page 10 3. Chlorinator Off: Test Salt Level Message T-CELL-3 5.50 T-CELL-9 10.00 T-CELL-5 6.75 T-CELL-15 10.00Insufficient operating time of the saltwater chlorinator: Increase the daily operating time of the saltwater chlorinator.; Salt level in pool water is less than 2,000 ppm: Check the salt level, and adjust as needed. Excessive sun exposure has evaporated chlorine: Use a pool cover when the pool is not in use. Number of swimmers has increased: Increase the …Help please! My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm.Jul 28, 2022 · I have an aqua rite salt chlorine system with a T-15 turbo cell. My average salt reading is 2100ppg and the instant reading is 210ppg. The check salt and inspect cell lights are constantly on (not bli … read more Chlorinator off High Salt/Amps. Post by Kabo24 » Sun 26 Jun, 2016 20:56 . Help please! My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt ...Saltmate saltwater electrolytic cells are constructed with premium grade high production material and are designed with high flow rate parallel plates. All Saltmate saltwater chlorinators can be installed onto new or existing pools without the need to change any other filtration equipment and are also compatible with mineral salt blends. Models.Again, test the water for an accurate salt reading, and add more salt according to your owner's manual recommendation of 2,700–3,400 ppm (parts per million), or the ideal of 3,200 ppm for Hayward AquaRite salt systems. 7. "High Salt" Light On. Test the salt levels in your pool, and make sure the salinity level is under 3,400 ppm.

If the salt level is too high or too low, your chlorinator can shut chlorine production off to protect the salt cell against damage. In the instance where salt gets too low, it can …. Hayworth tires elizabethton tennessee

chlorinator off high salt amps

Most models require only weak salt solutions of between 0.3% to 0.7% (3000ppm to 7000ppm) to effectively chlorinate a pool or spa. These levels are between one fifth to one tenth the level of salt in sea water. Follow the manufacturer’s recommendations strictly to avoid damage to the chlorinator and to ensure adequate chlorine production.salt level in the pool and the system may turn the chlorinator off. Maximum Current (Amps) before shutdown Page 10 3. Chlorinator Off: Test Salt Level Message T-CELL …JustAnswer-Q&A. 8.12K subscribers. Subscribed. 0. 1.2K views 2 years ago. From https://www.justanswer.com/ythi JustAnswer Customer from San Antonio, TX: I have the "Chlorinator off High...for the correct period and turns off the electrolytic cell, preventing excessive build ... constructed to withstand high temperature and UV radiation in the harsh Australian environment. ... V35 Viron Salt Chlorinator 10816 35gm/h 130,000 80,000 8 amps 10 amps V45 Viron Salt Chlorinator 10817 45gm/h 170,000 105,000 8 amps 10 amps I just replaced my T-cell 86 Turbo cell with a newly T-cell 54. When the system starting in race I get this message, "Chlorinator Off Elevated Salt/Amps." Then late for the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 8147, which EGO know is way too great. I... Aug 27, 2013 ... Hayward AquaRite Salt System NO FLOW? Tips ... The CONTROVERSIAL Scene That Took Gunsmoke Off The Air ... salt cell. Craig Wooster•101K views.Poolrite SureChlor S3500 RP 35g Pool Chlorinator (Retrofits AKS, Surechlor, Enduro & Endurochlor Chlorinators) 94. … chlorinator is a robust, long-lasting, efficient chlorinator that will perform day in and day out with no issues. Poolrite is a very familiar brand for many pool & spa owners in Australia.Mineral salts are substances extracted from bodies of water and below the Earth’s surface. Some examples of mineral salts include sodium, chlorine, calcium, phosphate, magnesium, s...Apr 8, 2021. #1. Hi everyone! I wanted to share my experience and success in fixing my "Chlorinator Off / High Salt/Amps" issue on my Aquarite panel. I'd replaced my Hayward T-9 with a legit one year before last and it had been working fine. Over the winter I'd been chlorinating the pool manually and maintaining pH--"easy mode" until the heat ... My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm. Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...A chlorinator off high salt amps indicates that the amount of chlorine being produced is too low. This can be caused by an insufficient level of salt in the pool water, or a malfunctioning chlorinator. To fix this issue, you should first check the concentration of salt in your pool – it should be between 2700 and 3400 parts per million (ppm). ...Also called Saltmaster on some chlorinators. This model has 4 connections. Quality Australian made cell. ... Due to high demand, we recommend reaching out to us directly for the most up-to-date stock. ... Take 20% off your first order. 20% off. Enter the code below at checkout to get 20% off your first order. CODESALE20Apr 17, 2012 · Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt... Apr 19, 2019 · I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more Low and High Salt Alarms can be observed when the salt in parts per million is outside of the expected range in a Body Of Water. Salt Chlorination takes place while the Salt Level is between 2400 and 3800 ppm . A Low Salt Alarm is generated when the Salt ppm is between 2400 and 2700 ppm for Standard. For Low Salt Monitoring it is between 800 ...ProLogic: How It Works. • All ProLogic systems are salt chlorination ready and can control 4-16 high voltage relays, 3-4 valve actuators and 1-2 heaters. • These systems can manage: Hayward Variable Speed Pumps, ColorLogic Lighting, Sense & Dispense, AquaConnect Homenet, as well as a wide variety of remotes.Oct 7, 2019 · I just replaced my T-cell 15 Turbo cell with a new T-cell 15. When the system begins to run I get this message, "Chlorinator Off High Salt/Amps." Then later in the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 4800, which I know is way too high. I... The chlorinator comes up "Check system high salt/amps". I have changed the cell, and I have backwashed numerous - Answered by a verified Pool and Spa Expert. We use cookies to give you the best possible experience on our website. ... I have a high salt amps message. chlorinator off when I start chlorinator the values that come up ….

Popular Topics